Lb-white I-34 Infraconic Spark Ignition Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
2200
PPrroobblleemm 22
HHeeaatteerr
LLiigghhttss bbuutt
wwiillll nnoott
SSttaayy LLiitt
Is Heater’s
Dust Filter
Reasonably
Clean
?
Remove Igniter and
Clean its Electrode.
Remove and Clean
the Filter.
Yes
No
Yes
Is High
Voltage Ignition
Lead in Good
Condition?
Is Igniter Clean?
Inner Combustion Cone
or Main Burner Orifice
are Plugged with Dirt.
Clean these
components.
No
Is Heater’s
Venturi Tube
Reasonably
Clean
?
Clean the Heater.
Yes
No
Is
Flame Sense
Ground Lead Properly
Connected and in
Good Condition?
Check the Lead for:
- Corroded Terminal
- Continuity/
Resistance
- Loose Connections
Repair or Replace as
Necessary.
Yes
No
Is Proper
Pressure Supplied
to the Heater?
Supply Proper Pressure
and Check for Blockages
in Gas Hose. Refill
L.P. Gas Containers if
Necessary.
Yes
No
No
Verify Continuity Value of
Lead. Verify Lead has Good
Connections, and No Cuts.
Replace if Necessary.
Yes
HHeeaatteerr
BBaacckkffllaasshheess
GGaass TThhrroouugghh
AAiirr IInnlleett..
PPrroobblleemm 33
Is Inner
Cone Seam
Fractured or is Tip
Damaged or
Missing?
Replace Combustion Cone.
Yes
No
Are
Injector
Body, Burner
Orifice,Filter, Venturi
Tube, or Inner Cone
Partially Plugged with
Dirt?
Clean these
Components.
No
Is Proper
Gas Pressure
Being Supplied to
the Heater?
Check for Proper
Gas Pressure.
Proper Pressure at
High Heat Should
Read 5 PSIG.
Yes
No
Combustion Cone Kits
Part Number
21088
Yes
Are Burner
Assembly
Nuts Loose?
Yes
Tighten the Nuts
Is the Burner
Plate or Burner
Gasket
Cracked?
Yes
Replace the Burner
Plate.or Gasket
No
No
Is Inner Cone
Weld Seam
Aligned to
Burner Plate
Notch?
No
Position the Inner Cone
Weld Seam in Burner
Plate Notch.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26

Comentarios a estos manuales

Sin comentarios