Does Igniter Spark?
1199
PPrroobblleemm 11
HHeeaatteerr
DDooeess
NNoott LLiigghhtt
Is
Proper Voltage
being sent from
ON/OFF Switch to
High Limit
Switch?
Is an
Audible Click
Heard When Solenoid
Valve is Supplied
Voltage?
Check for Voltage
and Resistance of
Switch and Electrical
Leads Between
Switches and Ignition
Control. Replace if
Defective.
Yes
No
Yes
Inner
Combustion
Cone , Venturi
Tube or Main
Burner Orifice
are Plugged with
Dirt. Clean the
Heater.
Is High
Limit Switch Sending
Voltage to Ignition
Control?
Check for Tripped High
Limit Switch. Reset the
High Limit Switch and
Determine Cause of
Tripping.
No
No
Is ON/OFF Switch
on Heater Positioned
to ON?
Position the
Switch to ON.
Yes
No
Is
Proper Voltage
Supplied to Zone
Control Panel and
Heater Power
Cord?
Provide Proper Voltage.
- Check Circuit Breakers
- Make sure building
environment control
thermostat is working
properly and calling for
heat
Yes
No
Yes
No
Yes
Replace Gas Solenoid
Valve
A. Check Igniter for
Defects, Cleanliness, and
Proper Gap.
B. Check Ignition Lead.
Verify Resistance of Lead.
Connections and No Cuts
Replace if Necessary.
C. If Igniter and Ignition Lead
are Good, Replace
Ignition Control.
Is Proper
Voltage Being
Sent through Power
Cord to On/Off
Switch?
Yes
No
Check Leads of
Power Cord for
Resistance.
Replace Power
Cord if Necessary.
Is Proper
Voltage Supplied to
Gas Control Valve
on Heater?
Replace Ignition
Control.
No
Yes
Are All Fuel Supply
Valves Open?
Open All Fuel Supply Valves
Yes
No
Is Proper
Gas Pressure
Supplied to Zone
Control Panel and
To Heater?
Yes
No
Provide Proper
Pressure.