Congratulations!
You have purchased the finest radiant heater available for the heating of livestock
in agricultural animal confinement buildings.
Your new L.B. White radiant heater incorporates the benefits from the most
experienced manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any
suggestions or comments you may have...call us toll free at 1-800-345-7200.
Owners Manual and Instructions
Spark Ignition Infraconic
Agricultural Building Radiant Heaters
ATTENTION ALL USERS
This heater has been tested and evaluated by L.B. White Co., Inc. as a direct
gas-fired radiant heater with intended use for the heating of livestock in agricultural
animal confinement buildings. If you are considering using this product for any
application other than its intended use, then please contact your fuel gas supplier,
or the L.B. White Co., Inc.
150-23922-A
MODELS OUTPUT (Btuh) FUEL
I34 34,200
Propane Vapor
Withdrawal
or Natural Gas
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 - Congratulations!

Congratulations!You have purchased the finest radiant heater available for the heating of livestockin agricultural animal confinement buildings.Your n

Pagina 2

BUSHINGRIGID END GOF HOSETO GASGSUPPLYVALVE, SHUT-OFFCONNECT HOSE TO GASGINLET, TIGHTEN SECURELYSTANDARD HOSEGAS TRAIN ASSEMBLY99FIG. 3This heater i

Pagina 3

INJECTOR BODY TABSFILTER ADAPTER PART #23931BEADED CABLE TIEDUST FILTER PART #239531100INSTALLING DUST FILTERFIG. 6With proper (5 PSIG) gas pressure

Pagina 4 - General Information

1111The building’s environmental temperature control systemwill shut the heater down after proper temperature has beenachieved.If heater is to

Pagina 5 - Radiant Heater Specifications

It is important to clean the heater and the optional dustfilter on a regular basis to maintain proper combustion andto eliminate future problems

Pagina 6 - Safety Precautions

11331. Have your gas supplier check all gas piping annuallyfor leaks or restrictions in gas lines. Also, at this timehave your gas supplier clean o

Pagina 7

IGNITION LEADIGNITION CONTROLGMOUNTING SCREWS Handle the module at the edges of the board Do not touch or allow any contact to the modulecomponents,

Pagina 8 - Installation Instructions

NUTS1 Disconnect the ignition lead from the ignitor. Removeignitor mounting screws. See Fig. 13.Fig. 132. Remove the igniter from the heater. Cle

Pagina 9 - INSTALLATION LAYOUT G

TERMINALMOUNTING LEGRESET BUTTONSENSING SURFACEFLAME This heater is equipped with a manual reset high limitswitch. Its purpose is to disconnect the

Pagina 10 - GAS TRAIN ASSEMBLY

FUEL SUPPLY VALVEG (OPEN THIS VALVE TO USEG PRESSURE GAUGE)GTEST KIT HOSEPRESSURE GAUGE KITG20736GAS SUPPLY HOSEGAS CONTROL VALVEOPENG117

Pagina 11 - FUNCTION AND INSTALLATION

1188READ THIS ENTIRE SECTION BEFOREBEGINNING TO TROUBLESHOOT PROBLEMS.The following troubleshooting flow charts provide systematicprocedures for isol

Pagina 13 - Cleaning Instructions

Does Igniter Spark?1199PPrroobblleemm 11HHeeaatteerrDDooeess NNoott LLiigghhttIs Proper Voltage being sent from ON/OFF Switch to High Limit Switch?

Pagina 14 - Maintenance Instructions

2200PPrroobblleemm 22HHeeaatteerrLLiigghhttss bbuuttwwiillll nnoott SSttaayy LLiittIs Heater’s Dust Filter Reasonably Clean?Remove Igniter andCle

Pagina 15 - IGNITION MODULE

Electrical Connection and Ladder Diagram2211CAUTION: REFER TO THE HEATER'S ELECTRICAL CONNECTIONDIAGRAM WHEN SERVICING TO AVOID WIRING ERRORS AND

Pagina 16 - HIGH VOLTAGE IGNITION LEAD

Heater Component FunctionBurner OrificeMetering device used to feed gas to combustion cones at aspecific flow rate.CanopyReflective aluminum heat shie

Pagina 17 - HIGH LIMIT SWITCH

Parts IdentificationPARTS SCHEMATIC2233243534363733323027262529283114171839 810 4131140 3 6 9162019 2 721 1A31A31B 1B42384123

Pagina 18 - GAS CONTROL VALVE

PARTS LIST2244Item Description Part Number1A Inner Cone 095571B Outer Cone 09556Combustion Cone Kit with Gasket 210882 Gasket 095603 Plate, Burner

Pagina 19 - Troubleshooting Guide

Contact your local L.B. White dealer for replacement partsand service or call the L.B. White Company, Inc. at 1-800-345-7200 for assista

Pagina 20

WARNINGFire and Explosion Hazard Not for home or recreational vehicle use. Installation of this heater in a home orrecreational vehicle may result i

Pagina 21

This owner's manual includes all options and accessoriescommonly used on or with this heater. However, dependingon the configuration purchased,

Pagina 22 - ELECTRICAL LADDER DIAGRAM

I34Maximum Input (Btuh) 34,200Ventilation Air to Support Combustion5 psig5 psig5 psig2.0 psig5 psig“A” 26-3/8 in.“B” 20 1/4 in.“C” 10 3/8 in.Net Weigh

Pagina 23 - Heater Component Function

PPrrooppaannee ggaass aanndd nnaattuurraall ggaass hhaavvee mmaann--mmaaddee ooddoorraannttss aaddddeedd ssppeecciiffiiccaallllyy ffoorr dd

Pagina 24 - Parts Identification

1. Do not attempt to install, repair or service this heateror the gas supply line unless you have continuingexpert training and knowledge of gas he

Pagina 25 - PARTS LIST

1. Read all safety precautions and follow L. B. Whiterecommendations when installing this heater. Ifduring the installation or relocating of t

Pagina 26 - Replacement Parts and Service

88INSTALLATION LAYOUT GFOR SAFE CLEARANCESI17 & I34 - 3 FT. MINIMUMGBROODER TOP TO CEILINGPOSITION THE GAS HOSE AND ELECTRICAL POWER CORDGOUTSIDE