Congratulations!
You have purchased the finest radiant heater available for the heating of livestock
in agricultural animal confinement buildings.
Your new L.B. White radiant heater incorporates the benefits from the most
experienced manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any
suggestions or comments you may have...call us toll free at 1-800- 345-7200.
Owners Manual and Instructions
Modulating Infraconic
Agricultural Building Radiant Heaters
ATTENTION ALL USERS
This heater has been tested and evaluated by L.B. White Co., Inc. as a direct gas-fired
radiant heater with intended use for the heating of livestock in agricultural animal
confinement buildings. If you are considering using this product for any application
other than its intended use, then please contact your fuel gas supplier, or the
L.B. White Co., Inc.
150-23199-B
MODELS OUTPUT (Btuh) FUEL
I40 40,000
Propane Vapor
Withdrawal
or Natural Gas
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Congratulations!

Congratulations!You have purchased the finest radiant heater available for the heating of livestockin agricultural animal confinement buildings.Your n

Pagina 2

1100The zone control panel is a remote mounted control systemallowing the operation of a specific amount of heaters withina certain zone of the buildi

Pagina 3 - General Information

Follow these start-up instruction steps for initial start-upbefore building repopulation. For normal start-up, simplyturn the thermosta

Pagina 4 - Radiant Heater Specifications

It is important to clean the heater on a regular basis tomaintain proper combustion and to eliminate futureproblems.The frequency o

Pagina 5 - Safety Precautions

FIG. 114. Repeat steps 2 and 3 until water runs clean.5. Remove the plastic bag. Inspect the cones andventuri tube to make sure these areas a

Pagina 6

1. Close the fuel supply valve to the heater beforeservicing unless it is necessary to have it open foryour service procedure.2. For

Pagina 7 - Installation Instructions

HOSEADAPTERFLATSVALVE BODYADAPTER NUTADAPTERTHERMOSTATIC HEADBYPASS ORIFICEIndividual Control HeatersThe bypass orifice is located in the valv

Pagina 8 - INSTALLATION LAYOUT 

1166SCREWRETAININGCLIPTHERMOCOUPLEINJECTORBODYTHERMALFUSEVENTURI TUBE This heater has two orifices. Remove only one orifice at a time for cleani

Pagina 9 - GAS TRAIN ASSEMBLY

PRESSURE VALVEAPPLY LOCTITEBYPASS GASSUPPLY TUBEPILOT BUTTONCOMPRESSIONNUTPRESSURE VALVECOMPRESSION NUTINJECTOR BODYPILOT CONTROL VALVEAA.. RReemmo

Pagina 10 - INSTALLING DUST FILTER

1188LEAD END OF THERMOCOUPLETHERMOFUSE5/16"COVERUPPER NUTTHERMOCOUPLELEADCOVERLOWER NUTTHERMOCOUPLE INSTALLEDUPPER RETAINING NUTKEY HOLE SLOTCOV

Pagina 11 - Shut-Down Instructions

TEST KIT HOSEFUEL SUPPLY VALVE(OPEN THIS VALVE TOUSE PRESSURE GAUGE)GAS SUPPLY HOSEGAS INLET OF HEATERPRESSURE GAUGE KIT20736OPENFIG. 24AA.. PPrree

Pagina 12 - Cleaning Instructions

GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater, can result in:— Death— Serious bodily injur

Pagina 13 - BB.. FFIILLTTEERR

READ THIS ENTIRE SECTION BEFOREBEGINNING TO TROUBLESHOOT PROBLEMS.The following troubleshooting flow charts provide systematicprocedures for isolati

Pagina 14 - Maintenance Instructions

Is There aBlockage in theInjector Body or Venturi Tube?2211PPrroobblleemm 11IInnnneerrCCoommbbuussttiioonnCCoonnee WWiillll NNoottLLiigghhttIs Th

Pagina 15 - SAFETY GAS CONTROL VALVE

2222PPrroobblleemm 22IInnnneerrCCoommbbuussttiioonnCCoonnee LLiigghhttss,,bbuutt wwiillll nnoottSSttaayy LLiittDid you Allow Sufficient Time for

Pagina 16 - THERMOSTATIC HEAD

2233PPrroobblleemm 33OOuutteerrCCoommbbuussttiioonnCCoonnee DDooeessNNoott HHeeaatt UUppoonn HHiigghhTThheerrmmoossttaattSSeettttiinngg..Is Prope

Pagina 17 - MAIN BURNER PRESSURE VALVE

2244Combustion Cone KitsPart Number24213NoPPrroobblleemm 55HHeeaatteerr DDooeess NNoott RReettuurrnn BBaacckk ttoo LLooww HHeeaatt..Does Main

Pagina 18 - THERMOCOUPLE

2255Heater Component FunctionBurner OrificesMetering devices used to feed gas to combustion cones at aspecific flow rate.CanopyReflective aluminum hea

Pagina 19 - GAS PRESSURE CHECKS

Parts Identification3536373332272629A28313818 3 2 1 229B29CINDIVIDUAL CONTROL24342515 5 411 6 916 734A34B2266PARTS SCHEMATIC

Pagina 20 - Troubleshooting Guide

2277PARTS LISTOPTIONS (Not Illustrated):Item Description Part No.Coupling, Quick Disconnect, Kit 21335Consisting Of:Shut-Off Valve 05548Nipple, 1/4 in

Pagina 21

Contact your local L.B. White dealer for replacement partsand ser vice or call the L.B. White Company, Inc. at (800) 345-7200 for ass

Pagina 22

This owner's manual includes all options and accessoriescommonly used on or with this heater. However, dependingon the configuration purchased,

Pagina 23 - Supplied to the

I40Maximum Input (Btuh) 40,000Ventilation Air to Support CombustionZone Control PROPANE GAS ORFull Output Pressure NATURAL GASZone Control, PROPANE GA

Pagina 24

WWAARRNNIINNGG Do not use this radiant heater for heating human livingquarters. Do not use in unventilated areas. The flow of combustion and ventil

Pagina 25 - Heater Component Function

1. Do not attempt to install, repair or service this heateror the gas supply line unless you have continuingexpert training and knowledge of g

Pagina 26 - Parts Identification

1. Read all safety precautions and follow L. B. Whiterecommendations when installing this heater. Ifduring the installation or relocatin

Pagina 27 - PARTS LIST

88-- If a leak is detected, check the componentsinvolved for cleanliness in the thread areasand proper application of pipe compoundb

Pagina 28 - Replacement Parts and Service

ABCHOSE & QUICK COUPLING KITCOLLARMALE ENDCOUPLINGVALVESHUT-OFFTO GASSUPPLYBUSHINGNIPPLEDUST CAP- ASSEMBLE COUPLING KIT  COMPONENTS & TIGH