Lb-white I-17 Infraconic Spark Ignition Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
20
Problem 2
Heater lights
but will not
stay lit
Is heater’s
dust filter
reasonably
clean
?
Remove igniter and
clean its electrode.
Remove and clean
the filter.
Yes
No
Yes
Is high
voltage ignition
lead in good
condition?
Is igniter clean?
Inner combustion
cone or main
burner orifice are
plugged with dirt.
Clean these
components.
No
Is
heater properly
grounded and are all
heater grounds in good
condition?
Check all grounds leads for:
- Corroded terminal
- Continuity/Resistance
- Loose connections
Repair or replace as
necessary.
Yes
No
Is proper
pressure supplied
to the heater?
Supply proper pressure
and check for blockages
in gas hose. Refill
L.P. gas containers.
Yes
No
No
Verify resistance value of
lead. Should be
1 ohm or less. Verify lead
has good connections, and
no cuts.
Replace if necessary.
Yes
Heater
backflashes
gas through
air inlet.
Problem 3
Is inner
cone seam
fractured or is tip
damaged or
missing?
Replace combustion cone.
Yes
No
Are
air housing
burner orifice,filter,
venturi tube, or inner cone
plugged with
dirt?
Clean these
Components.
No
Is proper
gas pressure
supplied to
heater?
Check for proper
gas pressure.
Proper pressure at
high heat should
read 5 PSIG.
Yes
No
Combustion Cone Kits
Part Number
21087
Yes
Are burner
assembly
nuts loose?
Yes
Tighten the nuts
Is the burner
plate or burner
gasket
cracked?
Yes
Replace the burner
plate or gasket
No
No
Is Inner cone weld
seam aligned to
burner plate
notch?
No
Position the inner cone
weld seam in burner
plate notch.