Does Igniter Spark?
19
Problem 1
Heater
does
not light
Is
proper voltage
being sent from
ON/OFF switch to
high limit
switch?
Is an
audible click
heard when solenoid valve
is supplied
voltage?
Check for voltage
and resistance of
switch and electrical
leads between
switches and ignition
control. Replace if
defective.
Yes
No
Yes
Inner combustion
cone, venturi tube
or main burner
orifice are plugged
with dirt. Clean the
heater.
No
Is ON/OFF switch
on Heater Positioned
to On
Position the
switch to On.
Yes
No
Is
proper voltage
supplied to zone
control panel and
heater power
cord?
Provide proper voltage.
- Check circuit breakers
- Make sure building
environment control
thermostat is working
properly and calling for
heat
Yes
No
Yes
No
Replace gas solenoid
valve
A. Check igniter for
defects, cleanliness, and
proper gap.
B. Check ignition lead.
Verify resistance of lead.
Should be 1 ohm or less.
Ensure lead has good
connections and no cuts.
Replace if necessary.
C. If igniter and ignition lead
are good, Replace
inition control.
Is proper
voltage
sent through power
cord to On/Off
switch?
Yes
No
Check leads of
power cord for
resistance.
Replace power
cord if necessary.
Is proper
voltage supplied to
gas control valve
on heater?
Replace ignition
control.
No
Yes
Are all fuel supply
valves open?
Open all fuel supply valves
Yes
No
Is proper
gas pressure
supplied to zone
control panel and
to heater?
Yes
No
Provide Proper
Pressure.