Problem 4
Outer
Combustion
Cone Does
Not Heat Up
on High
Thermostat
Setting.
Is Proper
Gas Pressure Being
Supplied to the
Heater?
Check for Proper Gas
Pressure to the Heater.
Proper Pressure at High
Heat Should Read 5 PSIG.
Yes
No
Is Burner
Orifice Plugged?
Remove Orifice and
Clean It.
Yes
No
A. Remove Thermostatic Head from
Thermostatic Valve Body. on Zone
Panel. If Outer Cone Lights, Replace
Thermostatic Head and Sensor
Assembly.
-- OR --
B. Replace Thermostatic Head
Valve Body.
Are There
Blockages in
Gas Hose, Piping,
Tubing Assembly, Injector
Body or Venturi
Tube?
Remove the Component
and Clean It.
Yes
No
No
Problem 5
Heater Does Not
Return Back to
Low Heat.
Does
Main Burner Shut Off
When Thermostatic Head is
Set Below Room
Temperature?
Remove Thermostatic Head from Modulating Valve Assembly:
A. If Heater Returns to Low Fire When you Push Down on Plunger Pin of Valve,
Replace Thermostatic Head/Sensor Assembly.
B. If Heater Still Does Not Cycle to Low Fire, the Modulating Valve is Sticking and
Should be Replaced.
20