Lb-white Guardian with Smart Sense - Spark Ignition (60K / Manual de usuario

Busca en linea o descarga Manual de usuario para Radiadores Lb-white Guardian with Smart Sense - Spark Ignition (60K / . L.B. White Guardian with Smart Sense - Spark Ignition (60K / 100K) User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Propane-Vapor
Withdrawal
and Natural Gas
Owner's Manual and Instructions
GUARDIAN
®
Agricultural Animal Confinement Building Heaters
with
Smart Sense
Automatic Variable Rate Heat
For Direct Connection to a Building Controller
View this manual online at www.lbwhite.com
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and
welcome any suggestions or comments you may have...call us, toll-free,
at 1-800-345-7200.
MODELS OUTPUT (Btuh) FUEL
AD060 60,000
AD100 100,000
Patent Pending
SCAN THIS QR CODE
with your smartphone or
visit http://goo.gl/nksqZ to
view maintenance videos
for L.B.White heaters.*
*Requires an app like QR Droid for Android or
QR Reader for iPhone.
150-29329
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance
with ANSI/IAS U.S. LC2-1998 as well as the Canadian Gas Association Standard for
Gas Fired Brooders, CAN1-2.20-M85 and is listed and approved as a direct gas-fired
circulating heater for the heating of agricultural animal confinement buildings.
To utilize the Smart Sense
automatic variable rate gas control valve, the heater
must be connected to an automated building controller capable of providing a
0-10 VDC, 0-20 milliamp signal, or 4-20 milliamp signal. If you are considering
using this product for any application other than it’s intended use, please contact
your fuel gas supplier, or the L.B. White Co., Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 30 31

Indice de contenidos

Pagina 1 - Congratulations!

Propane-VaporWithdrawaland Natural GasOwner's Manual and InstructionsGUARDIAN ®Agricultural Animal Confinement Building Heaters with Smart Sense™

Pagina 2

12. A qualified service agency must check for properoperating gas pressure upon installation of theheater.13. Light according to instructions on heate

Pagina 3

1. Assemble according to the illustration and tighten alleyebolts securely. See Fig. 3.FIG. 32. Be sure heater is securely fastened and is hangingleve

Pagina 4 - General Information

REGULATORNIPPLEREGULATOR VENTGAS HOSEADAPTERSEDIMENT TRAPTO CONTROLVALVE INLETGANIPPLEVALVE, MANUALSHUT-OFF11MANUAL SHUT-OFF VALVE, HOSEAND REGULATOR

Pagina 5 - Heater Specifications

12 The Smart Sense™variable rate heater incorporates asignal conditioner board in the control box. This signalconditioner takes the control signal s

Pagina 6 - Basic Operation

If the heater is to be shut down for cleaning, maintenance orrepair, follow steps 1 - 4. Otherwise, set the buildingcontroller to off.1. Close all ma

Pagina 7 - Safety Precautions

WARNINGThis heater may be washed only on the external caseassembly provided:A. The heater is disconnected from the electricalsupply.B. All access pane

Pagina 8

151. Remove the screws securing the motor mounting plateto the fan housing. See Fig. 11. (AD100 shown)2. Pull the fan and motor assembly from the hous

Pagina 9 - Installation Instructions

16AIR PROVING SWITCH WITH PADDLEThe air proving switch must work properly to allow anignition cycle. If the air proving switch contacts donot close o

Pagina 10 - INSTALLATION INSTRUCTIONS

The following describes the function of the transformerslocated in the control box during a call for heat. The larger 40 VA transformer supplies 24 v

Pagina 11 - SEDIMENT TRAP ASSEMBLY

The following explains a typical procedure to be followedin checking gas pressures. Consult the dataplate on the heater or page 4 in thismanual for

Pagina 13

19READ THIS ENTIRE SECTION BEFOREBEGINNING TO TROUBLESHOOT PROBLEMS.The troubleshooting flow charts on the following pagesprovide systematic procedure

Pagina 14 - Start-Up Instructions

20OPERATION SEQUENCE:— A call for heat occurs from the building controller.— 115 VAC is sent to:-- 40 VA transformer and to ignition control-- 20 VA

Pagina 15 - Maintenance Instructions

21ProblemLED constant onRed LED noton during a call forheat. Heaterdoes notoperate.Normal OperationIs heaterconnected to itspower supply?Connect it t

Pagina 16 - CLEARANCE

22Two TimesAir provingswitch doesnot closeduring a callfor heat. Are air provingswitch contactsstuck open?(Perform continuitycheck.)Does fan motor sta

Pagina 17 - IGNITER AND FLAME SENSOR

23Three TimesIgnition failure. The module hasgone into safetylockout.Is LP tankfull and properly sized and are all gas supply valves to heater open?F

Pagina 18 - IGNITION CONTROL

24If ignition control module does not reset, then replace the control. (Internal fault.)If ignition control module resets, then have qualified elect

Pagina 19 - Gas Pressure Checks

25Electrical Connection and Ladder Diagram++1 2 6 7 5 3

Pagina 20 - Troubleshooting Instructions

26Heater Component FunctionAir Proving Switch Safety device used to insure that the proper air flow is beingachieved before the gas valve is opened.

Pagina 21

27Parts IdentificationPARTS SCHEMATIC

Pagina 22

28Parts IdentificationPARTS LISTItem Description Part Number1 Regulator, 2nd stage, vent over outlet Propane Gas 06553*Regulator, 2nd stage, vent over

Pagina 23

WARNINGFire and Explosion Hazard Not for home or recreational vehicle use. Installation of this heater in a home orrecreational vehicle may result i

Pagina 24

Contact your local L.B. White dealer for replacement partsand service or call the L.B. White Co., Inc. at 1-800-345-7200for assistance. Be sure that

Pagina 26 - 1 2 6 7 5 3

This Owner's Manual includes all options and accessoriescommonly used on this heater. However, depending on theconfiguration purchased, some opt

Pagina 27 - Heater Component Function

Maximum Input (BTUH) 60,000 100,000Minimum Input (BTUH) 15,000 25,000240 400 11.0 10.0 11.0 10.010.0 9.0 10.0 9.0 0.8

Pagina 28 - Parts Identification

5This heater uses Smart Sense™ technology for variablerate heat control. L.B.White has worked with agriculturalbuilding control manufacturers for the

Pagina 29

6Propane gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.If a gas leak occurs, you should be able to sme

Pagina 30 - Replacement Parts and Service

1. Do not attempt to install, repair, or service this heateror the gas supply line unless you have continuingexpert training and knowledge of gas heat

Pagina 31

1. Read all safety precautions and follow L. B. Whiterecommendations when installing this heater. Ifduring the installation or relocating of heater,

Comentarios a estos manuales

Sin comentarios